Each power station you add becomes one Indigo device. There are two kinds:
In Indigo
Your power station
EcoFlow River 3
A River 3
EcoFlow Delta 3
A Delta 3
Both show the same readings, and the Delta 3 has one more, AC Output Voltage. The names below are the ones Indigo shows when you build a trigger or look at the device’s states. A reading stays blank if your model never reports it.
Battery
Shown as
What it means
Battery SOC (%)
How full the battery is. SOC stands for state of charge.
Battery Health (%)
How much of its original capacity the battery still holds, as the power station reports it.
Battery Remaining (Wh)
The energy left in the battery, in watt-hours.
Battery Full Capacity (Wh)
How much the battery holds when full today, in watt-hours.
Battery Design Capacity (Wh)
How much the battery held when new, in watt-hours.
Battery Voltage (V)
The battery’s voltage right now.
Cell Temp Min (degC) and Cell Temp Max (degC)
The coolest and warmest battery cells, in degrees Celsius.
Charge Cycles
How many full charge cycles the battery has been through.
Charging State
charging, discharging or idle. It shows unknown if the power station sends a value the plugin does not recognise.
Power coming in and going out
All in watts, as they are right now.
Shown as
What it means
Total Input Power (W)
Everything coming in, from solar and the mains together.
Total Output Power (W)
Everything going out, across every socket.
Solar Input (W)
What is coming in from solar panels.
AC Input (W)
What is coming in from the mains.
AC Output (W)
What the mains sockets on the power station are supplying.
AC Output Voltage (V)
The voltage at the mains sockets. Delta 3 only.
12V DC Output (W)
What the 12 volt car-style socket is supplying.
USB-C Output (W) and USB-C 2 Output (W)
What each USB-C socket is supplying.
USB-A 1 Output (W) and USB-A 2 Output (W)
What each USB-A socket is supplying.
DC Port Output (W) and DC Port 2 Output (W)
The power on the power station’s other DC ports, as it reports them.
BMS Power (W)
The power going into or out of the battery, as the battery’s own management reports it.
Time left
Shown as
What it means
Time to Full (min)
Minutes until the battery is full at the present rate of charge.
Time Remaining (min)
Minutes until the battery runs down at the present rate of use.
Temperatures
Shown as
What it means
DC Converter Temp (degC) and AC Converter Temp (degC)
The temperature inside the power station’s DC and AC circuits, in degrees Celsius.
Fan Level
The fan speed, as a number the power station reports.
The power station’s own settings
These show how the power station is set, whether you changed a setting from Indigo, the EcoFlow app or the buttons on the unit. True means on and False means off.
Shown as
What it means
AC Output Enabled
Whether the mains sockets are switched on.
DC Output Enabled
Whether the 12 volt DC output is switched on.
XBoost Enabled
Whether EcoFlow’s XBoost feature is on.
Max Charge Level (%)
The level the power station stops charging at.
Min Discharge Level (%)
The lowest level the power station will run the battery down to.
AC Charging Power (W)
The most power the power station will take from the mains while charging.
Buzzer Enabled
Whether the power station beeps.
Screen Timeout (s)
Seconds before the screen turns off.
AC Standby Timer (s) and Device Standby Timer (s)
Seconds of no use before the mains sockets, or the whole power station, switch off.
Sleep State
The power station’s sleep state, as a number it reports.
Running totals
These count up over the power station’s life.
Shown as
What it means
AC Output Energy Total (Wh)
Energy supplied through the mains sockets.
AC Input Energy Total (Wh)
Energy taken from the mains.
Solar Input Energy Total (Wh)
Energy taken from solar.
12V DC Output Energy Total (Wh)
Energy supplied through the 12 volt socket.
USB-C Output Energy Total (Wh) and USB-A Output Energy Total (Wh)
Energy supplied through the USB sockets.
Device Working Time (s)
How long the power station has been running, in seconds.
Faults and firmware
Shown as
What it means
Low Power Alarm
True when the power station is raising its low battery alarm.
The fault numbers the power station reports for itself and for each of its parts — the battery, the power board, the solar charger and the mains inverter.
True while readings are arriving. It is False when the plugin starts, until the first reading comes in, and turns False again if no reading arrives for 10 minutes.
Last Update
The time of the last reading, such as 14:05:32.
Readings copied to variables
If you tick Mirror Key States to Variables in a device’s settings, the plugin also writes these readings into Indigo variables, in a variable folder called EcoFlow, which it makes if you do not have one:
Battery SOC, Total Input Power, Total Output Power, AC Output, Solar Input, Time Remaining and Charging State
AC Output Enabled, DC Output Enabled, XBoost Enabled, Buzzer Enabled and Low Power Alarm, as True or False
Each variable is named ecoflow_, then the device’s name, then the reading. Spaces and symbols in the device’s name become underscores, and only the first 28 characters of the name are used, so a device called Delta 3 gives variables such as ecoflow_Delta_3_battery_soc and ecoflow_Delta_3_solar_in_w.